| PAL HPLC Autosampler Option |
|
| |
| 4-fold Valve Drive |
 |
4-fold Valve Drive with stream selector valve |
|
|
Automated parallel or staggered injections with 4 valves |
Stream selector valve for staggered sample injection mode
|
Single syringe design enables "cherry picking mode"
|
|
|
 |
Flow diagram 4-fold parallel injections |
|
The PAL 4-fold valve option was developed for automated parallel LC-MS analysis especially required for multiplexed LC-MS interfaces. The accessory consists of 4 injection valves which are loaded in serial mode and switched to inject simultaneously. This allows working with 4 LC columns in parallel which results in enhanced throughput. CTC’s single syringe design allows even for parallel analysis the “cherry picking” sampling mode (random plate access to single wells). Additionally the 4-valve option can be combined with an 8-port stream selector valve for staggered sample injections. Important chromatogram areas can be cut-out and reach the LC-MS inlet. Beside enhanced throughput, this feature helps to keep the MS inlet clean for a prolonged period of time. |
|
| |
Additionally the above described system can be equipped with a 8-port stream selector valve, which allows staggered sample injections. Using this configuration, important chromatogram parts only can be cut out and reach the LC-MS inlet. Beside the enhanced throughput, this feature helps to keep clean the LC-MS inlet for a prolonged period of time. |
| |
Staggered injections require the PAL 4-fold Valve Drive Option and additionally the PAL 8-port Selector Valve
|
| |
| Detail |
| Part no.: |
PAL 4VlvDrv |
| Consisting of |
4 pcs Valve drives
1 pc PEEK solvent manifold
1set PEEK tubing kit including PEEK fittings
1 set Connection cable
(requires VICI Valco, type WK, or Cheminert valves and sample loops)
|
| Part no.: |
PAL SelVlv |
| Consisting of |
1pc 8-port Selector valve C5F
4pcs Teflon tubing waste lines
1pc Valve drive
1pc Connection cable
|
|
| |
| Specification |
| System requirements: |
HTC / HTS / HTX or HTC-xt / HTS-xt HTX-xt respectively equipped with PAL DLW / PAL Dilutor and / or Fast Wash Station |
| Software requirements: |
Cycle Composer control software Vers. 1.4. or higher
PAL Firmware 2.4 or higher
Appropriate third party instrument driver |
| Valve Drive specifications: |
Switching speed: 211ms
Max. Torque: 1.6nm |
| Used for valve type: |
VICI Valco W-type and Cheminert
|
|
| |
| More information from CTC : http://www.palsystem.com/index.php?id=211 |
| |